<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://support.staging.acd.net/index.php?action=history&amp;feed=atom&amp;title=Demarc_Extension_Wiring_Specifications</id>
	<title>Demarc Extension Wiring Specifications - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://support.staging.acd.net/index.php?action=history&amp;feed=atom&amp;title=Demarc_Extension_Wiring_Specifications"/>
	<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;action=history"/>
	<updated>2026-10-14T11:51:39Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.43.11</generator>
	<entry>
		<id>https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=408&amp;oldid=prev</id>
		<title>imported&gt;Henry.joshua at 10:14, 5 August 2012</title>
		<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=408&amp;oldid=prev"/>
		<updated>2012-08-05T10:14:20Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 10:14, 5 August 2012&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Demarc Extensions, which extend the wiring from the [[Network Interface]] to the inside of a building or through a building to where your equipment sits &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;is &lt;/del&gt;a critical portion of the network. Often the speeds or stability that a customer can get from ACD is significantly affected by the quality of &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;your &lt;/del&gt;inside wiring.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Demarc Extensions, which extend the wiring from the [[Network Interface]] to the inside of a building or through a building to where your equipment sits&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, are &lt;/ins&gt;a critical portion of the network. Often&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;the speeds or stability that a customer can get from ACD is significantly affected by the quality of &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;the &lt;/ins&gt;inside wiring.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The wiring that ACD recommends is the following based upon information gathered on testing and debugging and the written specifications from vendors. Changing out your internal wiring may not make a difference if the wiring you have is of good quality, &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;however &lt;/del&gt;if the wiring is of low quality, then changing out your wiring will make a substantial difference.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The wiring that ACD recommends is the following&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;based upon information gathered on testing and debugging and the written specifications from vendors. Changing out your internal wiring may not make a difference&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;if the wiring you have is of good quality&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. However&lt;/ins&gt;, if the wiring is of low quality, then changing out your wiring will make a substantial difference.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==Recommendations for DSL or EFM Service Wiring==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==Recommendations for DSL or EFM service Wiring==&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;Use Solid Core &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Wire&lt;/ins&gt;&#039;&#039;&#039;, do not &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;use &lt;/ins&gt;stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt; &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;For DSL or EFM copper loops&#039;&#039;&#039; use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;the larger the &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;gauge &lt;/ins&gt;of wire&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;the better your connection is likely to be. Short lengths of this type of cable can be &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;bought &lt;/ins&gt;at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;Use Solid Core &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;wire&lt;/del&gt;&#039;&#039;&#039;, do not &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;uses &lt;/del&gt;stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Keystone type jacks are the best&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/ins&gt;These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;For DSL or EFM copper loops&#039;&#039;&#039; use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;guage &lt;/del&gt;of wire the better your connection is likely to be. Short lengths of this type of cable can be &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;bough &lt;/del&gt;at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Keystone type jacks are the best&#039;&#039;&#039; These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;For Regular DSL&amp;#039;&amp;#039;&amp;#039; Cat 3 RJ-11 Keystone Jacks work fine.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;For Regular DSL&amp;#039;&amp;#039;&amp;#039; Cat 3 RJ-11 Keystone Jacks work fine.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Ground your power outlets&#039;&#039;&#039; The power outlets that you have should be grounded in your house, this &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;decrease &lt;/del&gt;electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Ground your power outlets&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/ins&gt;The power outlets that you have should be grounded in your house, this &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;decreases &lt;/ins&gt;electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Shielded Wiring&#039;&#039;&#039;:&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;for &lt;/del&gt;best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Shielded Wiring&#039;&#039;&#039;: &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;For &lt;/ins&gt;best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Avoid Running Data Lines near Power Lines&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:&lt;/del&gt;&#039;&#039;&#039; Avoiding perpendicular wiring crossing major power lines&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;may significantly improve &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;reliablity&lt;/del&gt;. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, that &lt;/del&gt;are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;powerlines &lt;/del&gt;or curving them into these lines&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;when needed is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Avoid Running Data Lines near Power Lines&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/ins&gt;Avoiding perpendicular wiring crossing major power lines may significantly improve &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;reliability&lt;/ins&gt;. For example&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and &lt;/ins&gt;are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;and &lt;/ins&gt;Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;running data lines in parallel to these &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;power lines &lt;/ins&gt;or curving them into these lines when needed&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Do not plug your data lines into Surge Suppressors where not needed&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:&lt;/del&gt;&#039;&#039;&#039; Although surge &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;supressors &lt;/del&gt;can save your modem they can also cause interference on your line.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Do not plug your data lines into Surge Suppressors where not needed&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/ins&gt;Although surge &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;suppressors &lt;/ins&gt;can save your modem&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;they can also cause interference on your line.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Minimize the number of &quot;Splits&quot; on your data or voice line&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:&lt;/del&gt;&#039;&#039;&#039; If you split your home phone line or DSL a number of times to connect to various outlets, it is best minimize the number of splits, and to make sure that where these splits occur&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;the wiring is of high quality at each junction point. Each split&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/del&gt;creates an &quot;antenna&quot;, collecting magnetic interference.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Minimize the number of &quot;Splits&quot; on your data or voice line&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/ins&gt;If you split your home phone line or DSL a number of times to connect to various outlets, it is best &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;to &lt;/ins&gt;minimize the number of splits, and to make sure that where these splits occur the wiring is of high quality at each junction point. Each split creates an &quot;antenna&quot;, collecting magnetic interference.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for T1 Wire==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for T1 Wire==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;T1 Wire&#039;&#039;&#039; which is a &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;specific &lt;/del&gt;type of wire should be used for any demarcation extensions past 25 feet from the [[Network Interface]]. T1 wire is a specific type of wire made for just T1 lines. It uses RJ-48 Jacks, which &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;is &lt;/del&gt;are different than the types of jacks used for Ethernet (ethernet uses RJ-45 Jacks).&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;T1 Wire&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;which is a &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;unique &lt;/ins&gt;type of wire&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;, &lt;/ins&gt;should be used for any demarcation extensions past 25 feet from the [[Network Interface]]. T1 wire is a specific type of wire made for just T1 lines. It uses RJ-48 Jacks, which are different than the types of jacks used for Ethernet(ethernet uses RJ-45 Jacks).&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Using Ethernet Wire for T1 Wiring extensions&#039;&#039;&#039; Although generally acceptable, you should never use &quot;stranded&quot; wire, you &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;shoud &lt;/del&gt;use &quot;solid core&quot; wire, and never more than 25 feet from the Network Interface.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;Using Ethernet Wire for T1 Wiring extensions&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;:&lt;/ins&gt;&#039;&#039;&#039; Although generally acceptable, you should never use &quot;stranded&quot; wire, you &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;should &lt;/ins&gt;use &quot;solid core&quot; wire, and never more than 25 feet from the Network Interface.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key mediawiki:diff:1.41:old-407:rev-408:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>imported&gt;Henry.joshua</name></author>
	</entry>
	<entry>
		<id>https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=407&amp;oldid=prev</id>
		<title>imported&gt;Schoen.kevin at 02:15, 27 September 2011</title>
		<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=407&amp;oldid=prev"/>
		<updated>2011-09-27T02:15:42Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 02:15, 27 September 2011&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service Wiring==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service Wiring==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;Use &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&quot;&lt;/del&gt;Solid Core&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&quot; &lt;/del&gt;wire&#039;&#039;&#039;, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;Use Solid Core wire&#039;&#039;&#039;, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;For DSL or EFM copper loops&amp;#039;&amp;#039;&amp;#039; use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the guage of wire the better your connection is likely to be. Short lengths of this type of cable can be bough at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;For DSL or EFM copper loops&amp;#039;&amp;#039;&amp;#039; use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the guage of wire the better your connection is likely to be. Short lengths of this type of cable can be bough at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Keystone type jacks are the best&amp;#039;&amp;#039;&amp;#039; These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Keystone type jacks are the best&amp;#039;&amp;#039;&amp;#039; These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key mediawiki:diff:1.41:old-406:rev-407:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>imported&gt;Schoen.kevin</name></author>
	</entry>
	<entry>
		<id>https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=406&amp;oldid=prev</id>
		<title>imported&gt;Schoen.kevin: /* Recommendations for DSL or EFM service Wiring */</title>
		<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=406&amp;oldid=prev"/>
		<updated>2011-09-27T02:15:31Z</updated>

		<summary type="html">&lt;p&gt;&lt;span class=&quot;autocomment&quot;&gt;Recommendations for DSL or EFM service Wiring&lt;/span&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 02:15, 27 September 2011&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l6&quot;&gt;Line 6:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 6:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service Wiring==&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service Wiring==&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Use &quot;Solid Core&quot; &lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;wiring&lt;/del&gt;, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&lt;/ins&gt;Use &quot;Solid Core&quot; &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;wire&#039;&#039;&#039;&lt;/ins&gt;, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*For DSL or EFM copper loops use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the guage of wire the better your connection is likely to be. Short lengths of this type of cable can be bough at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;&lt;/ins&gt;For DSL or EFM copper loops&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039; &lt;/ins&gt;use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the guage of wire the better your connection is likely to be. Short lengths of this type of cable can be bough at most home improvement stores.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Keystone type jacks are the best&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/del&gt;These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;&lt;/ins&gt;Keystone type jacks are the best&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039; &lt;/ins&gt;These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*For Regular DSL Cat 3 RJ-11 Keystone Jacks work fine.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;&lt;/ins&gt;For Regular DSL&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039; &lt;/ins&gt;Cat 3 RJ-11 Keystone Jacks work fine.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Ground your power outlets&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;. &lt;/del&gt;The power outlets that you have should be grounded in your house, this decrease electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039;&lt;/ins&gt;Ground your power outlets&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&#039;&#039;&#039; &lt;/ins&gt;The power outlets that you have should be grounded in your house, this decrease electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Shielded Wiring&amp;#039;&amp;#039;&amp;#039;:for best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Shielded Wiring&amp;#039;&amp;#039;&amp;#039;:for best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Avoid Running Data Lines near Power Lines:&amp;#039;&amp;#039;&amp;#039; Avoiding perpendicular wiring crossing major power lines, may significantly improve reliablity. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off, that are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these powerlines or curving them into these lines, when needed is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Avoid Running Data Lines near Power Lines:&amp;#039;&amp;#039;&amp;#039; Avoiding perpendicular wiring crossing major power lines, may significantly improve reliablity. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off, that are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these powerlines or curving them into these lines, when needed is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;/table&gt;</summary>
		<author><name>imported&gt;Schoen.kevin</name></author>
	</entry>
	<entry>
		<id>https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=405&amp;oldid=prev</id>
		<title>imported&gt;Schoen.kevin at 02:08, 27 September 2011</title>
		<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=405&amp;oldid=prev"/>
		<updated>2011-09-27T02:08:15Z</updated>

		<summary type="html">&lt;p&gt;&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 02:08, 27 September 2011&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l1&quot;&gt;Line 1:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 1:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Demarc Extensions, which extend the wiring from the [[Network Interface]] to the inside of a building or through a building to where your equipment sits is a critical portion of the network. Often the speeds or stability that a customer can get from ACD is significantly affected by the quality of your inside wiring.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;Demarc Extensions, which extend the wiring from the [[Network Interface]] to the inside of a building or through a building to where your equipment sits is a critical portion of the network. Often the speeds or stability that a customer can get from ACD is significantly affected by the quality of your inside wiring.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The wiring that ACD recommends is the following based upon information gathered on testing and debugging and the written specifications from vendors. Changing out your internal wiring may not make a difference if the wiring you have is of good quality, however if the wiring is of low quality, then changing out your wiring will make a substantial difference.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;The wiring that ACD recommends is the following based upon information gathered on testing and debugging and the written specifications from vendors. Changing out your internal wiring may not make a difference if the wiring you have is of good quality, however if the wiring is of low quality, then changing out your wiring will make a substantial difference.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Although most wire will work, below are our recommendations:&lt;/del&gt;&lt;/div&gt;&lt;/td&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-added&quot;&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;==Recommendations for DSL or EFM service &lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Wiring==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Use &amp;quot;Solid Core&amp;quot; wiring, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Use &amp;quot;Solid Core&amp;quot; wiring, do not uses stranded wire. Stranded wire is what is in cheap phone lines.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot; id=&quot;mw-diff-left-l14&quot;&gt;Line 14:&lt;/td&gt;
&lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 12:&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Ground your power outlets. The power outlets that you have should be grounded in your house, this decrease electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*Ground your power outlets. The power outlets that you have should be grounded in your house, this decrease electromagnetic interference on all wiring in your house.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Shielded Wiring&amp;#039;&amp;#039;&amp;#039;:for best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Shielded Wiring&amp;#039;&amp;#039;&amp;#039;:for best results, use shielded wire, and ground one end of the shield on a ground.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;−&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;&lt;del style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Avioid &lt;/del&gt;Running Data Lines near Power Lines:&#039;&#039;&#039; Avoiding perpendicular wiring crossing major power lines, may significantly improve reliablity. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off, that are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these powerlines or curving them into these lines, when needed is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&#039;&#039;&#039;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;Avoid &lt;/ins&gt;Running Data Lines near Power Lines:&#039;&#039;&#039; Avoiding perpendicular wiring crossing major power lines, may significantly improve reliablity. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off, that are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these powerlines or curving them into these lines, when needed is better than doing a straight perpendicular crossing.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Do not plug your data lines into Surge Suppressors where not needed:&amp;#039;&amp;#039;&amp;#039; Although surge supressors can save your modem they can also cause interference on your line.  &lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Do not plug your data lines into Surge Suppressors where not needed:&amp;#039;&amp;#039;&amp;#039; Although surge supressors can save your modem they can also cause interference on your line.  &lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Minimize the number of &amp;quot;Splits&amp;quot; on your data or voice line:&amp;#039;&amp;#039;&amp;#039; If you split your home phone line or DSL a number of times to connect to various outlets, it is best minimize the number of splits, and to make sure that where these splits occur, the wiring is of high quality at each junction point. Each split, creates an &amp;quot;antenna&amp;quot;, collecting magnetic interference.&lt;/div&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;&lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;*&amp;#039;&amp;#039;&amp;#039;Minimize the number of &amp;quot;Splits&amp;quot; on your data or voice line:&amp;#039;&amp;#039;&amp;#039; If you split your home phone line or DSL a number of times to connect to various outlets, it is best minimize the number of splits, and to make sure that where these splits occur, the wiring is of high quality at each junction point. Each split, creates an &amp;quot;antenna&amp;quot;, collecting magnetic interference.&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;==Recommendations for T1 Wire==&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;*&#039;&#039;&#039;T1 Wire&#039;&#039;&#039; which is a specific type of wire should be used for any demarcation extensions past 25 feet from the [[Network Interface]]. T1 wire is a specific type of wire made for just T1 lines. It uses RJ-48 Jacks, which is are different than the types of jacks used for Ethernet (ethernet uses RJ-45 Jacks).&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;
&lt;tr&gt;&lt;td colspan=&quot;2&quot; class=&quot;diff-side-deleted&quot;&gt;&lt;/td&gt;&lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;&lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;&lt;ins style=&quot;font-weight: bold; text-decoration: none;&quot;&gt;*&#039;&#039;&#039;Using Ethernet Wire for T1 Wiring extensions&#039;&#039;&#039; Although generally acceptable, you should never use &quot;stranded&quot; wire, you shoud use &quot;solid core&quot; wire, and never more than 25 feet from the Network Interface.&lt;/ins&gt;&lt;/div&gt;&lt;/td&gt;&lt;/tr&gt;

&lt;!-- diff cache key mediawiki:diff:1.41:old-404:rev-405:php=table --&gt;
&lt;/table&gt;</summary>
		<author><name>imported&gt;Schoen.kevin</name></author>
	</entry>
	<entry>
		<id>https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=404&amp;oldid=prev</id>
		<title>imported&gt;Schoen.kevin: Created page with &quot; Demarc Extensions, which extend the wiring from the Network Interface to the inside of a building or through a building to where your equipment sits is a critical portion of...&quot;</title>
		<link rel="alternate" type="text/html" href="https://support.staging.acd.net/index.php?title=Demarc_Extension_Wiring_Specifications&amp;diff=404&amp;oldid=prev"/>
		<updated>2011-09-27T01:45:00Z</updated>

		<summary type="html">&lt;p&gt;Created page with &amp;quot; Demarc Extensions, which extend the wiring from the &lt;a href=&quot;/index.php?title=Network_Interface&amp;amp;action=edit&amp;amp;redlink=1&quot; class=&quot;new&quot; title=&quot;Network Interface (page does not exist)&quot;&gt;Network Interface&lt;/a&gt; to the inside of a building or through a building to where your equipment sits is a critical portion of...&amp;quot;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;&lt;br /&gt;
Demarc Extensions, which extend the wiring from the [[Network Interface]] to the inside of a building or through a building to where your equipment sits is a critical portion of the network. Often the speeds or stability that a customer can get from ACD is significantly affected by the quality of your inside wiring. &lt;br /&gt;
&lt;br /&gt;
The wiring that ACD recommends is the following based upon information gathered on testing and debugging and the written specifications from vendors. Changing out your internal wiring may not make a difference if the wiring you have is of good quality, however if the wiring is of low quality, then changing out your wiring will make a substantial difference.&lt;br /&gt;
&lt;br /&gt;
Although most wire will work, below are our recommendations:&lt;br /&gt;
&lt;br /&gt;
==Recommendations for DSL or EFM service&lt;br /&gt;
&lt;br /&gt;
*Use &amp;quot;Solid Core&amp;quot; wiring, do not uses stranded wire. Stranded wire is what is in cheap phone lines. &lt;br /&gt;
*For DSL or EFM copper loops use Cat 5, Cat5E, or Cat 6 wiring from your network interface to your Modem Jack. Basically the larger the guage of wire the better your connection is likely to be. Short lengths of this type of cable can be bough at most home improvement stores. &lt;br /&gt;
*Keystone type jacks are the best. These can be purchased at Home Depot, Menards or Lowes in the Electric department. Leviton is the common brand. For cheaper prices you can order this stuff from the web. These stores are usually expensive. &lt;br /&gt;
*For Regular DSL Cat 3 RJ-11 Keystone Jacks work fine. &lt;br /&gt;
*Ground your power outlets. The power outlets that you have should be grounded in your house, this decrease electromagnetic interference on all wiring in your house. &lt;br /&gt;
*&amp;#039;&amp;#039;&amp;#039;Shielded Wiring&amp;#039;&amp;#039;&amp;#039;:for best results, use shielded wire, and ground one end of the shield on a ground. &lt;br /&gt;
*&amp;#039;&amp;#039;&amp;#039;Avioid Running Data Lines near Power Lines:&amp;#039;&amp;#039;&amp;#039; Avoiding perpendicular wiring crossing major power lines, may significantly improve reliablity. For example high voltage equipment can cause magnetic interference on your DSL, Phone, EFM or T1 lines. Common devices that turn on and off, that are likely to cause interference are Copiers, Air Conditioning Systems, Furnaces, Main feed lines into buildings. The goal is to avoid electromagnetic interference. Usually running data lines in parallel to these powerlines or curving them into these lines, when needed is better than doing a straight perpendicular crossing. &lt;br /&gt;
*&amp;#039;&amp;#039;&amp;#039;Do not plug your data lines into Surge Suppressors where not needed:&amp;#039;&amp;#039;&amp;#039; Although surge supressors can save your modem they can also cause interference on your line. &lt;br /&gt;
*&amp;#039;&amp;#039;&amp;#039;Minimize the number of &amp;quot;Splits&amp;quot; on your data or voice line:&amp;#039;&amp;#039;&amp;#039; If you split your home phone line or DSL a number of times to connect to various outlets, it is best minimize the number of splits, and to make sure that where these splits occur, the wiring is of high quality at each junction point. Each split, creates an &amp;quot;antenna&amp;quot;, collecting magnetic interference.&lt;/div&gt;</summary>